Torque converter lock up control 700R4

Jump to: navigation, search
m
m (figure out the menu setup)
Line 20: Line 20:
 
[[image:700_connectors.jpg]]
 
[[image:700_connectors.jpg]]
  
===Pressure switches===
+
==Pressure switches==
  
 
Notice these are silver in color. This means they are NO = Normally Open.  When pressure is applied the switch closes the internal contacts to complete the circuit. Both of these pressure switches are "on -off" design. Pressure turns them 'on' , no pressure they are "off"
 
Notice these are silver in color. This means they are NO = Normally Open.  When pressure is applied the switch closes the internal contacts to complete the circuit. Both of these pressure switches are "on -off" design. Pressure turns them 'on' , no pressure they are "off"
Line 28: Line 28:
 
[[Image:700_pressure_switches.jpg]]
 
[[Image:700_pressure_switches.jpg]]
  
===Lock up Solenoids===
+
==Lock up Solenoids==
  
 
Solenoid designs:  1 wire and common 2 wire.  Solenoid on the left has 1 red wire. this is a self grounding lock up solenoid. The 2 wire solenoid has a red wire and a black wire.  Red is for 12 volts, black is for ground.
 
Solenoid designs:  1 wire and common 2 wire.  Solenoid on the left has 1 red wire. this is a self grounding lock up solenoid. The 2 wire solenoid has a red wire and a black wire.  Red is for 12 volts, black is for ground.
  
 
[[image:700_solenoid_wires.jpg]]
 
[[image:700_solenoid_wires.jpg]]
 +
 +
==Valve body location for switch==
 +
  
 
Location for pressure switch on valve body for 4th gear lockup only of the converter clutch. this location has pressure when the trans is in 4th gear
 
Location for pressure switch on valve body for 4th gear lockup only of the converter clutch. this location has pressure when the trans is in 4th gear