How to find an electrical drain

Jump to: navigation, search
m (Reverted edits by 216.70.43.22 (Talk); changed back to last version by Jon)
m (Grammar / punctuation edits and just cleaning up the appearance)
Line 8: Line 8:
  
 
'''ACCEPTABLE AMPERAGE DRAW'''
 
'''ACCEPTABLE AMPERAGE DRAW'''
  Exact maximum allowable draw is determined by calculating several factors but as a general rule,the maximum should not exceed 50mA or .050 Amps'''
+
  Exact maximum allowable draw is determined by calculating several factors.
 +
But, as a general rule,the maximum should not exceed 50mA or .050 Amps'''
  
 
# '''TOOLS AND EQUIPMENT'''
 
# '''TOOLS AND EQUIPMENT'''
Line 34: Line 35:
 
#### Was the reading .050 A or less?
 
#### Was the reading .050 A or less?
 
  Yes - You are ''not'' experiencing an excessive power draw at this time.
 
  Yes - You are ''not'' experiencing an excessive power draw at this time.
  No - It was higher: you have a confirmed power draw - continue with the next step.  
+
  No  - It was higher: you have a confirmed power draw - continue with the next step.  
 
Disconnect EITHER one of the DVOM cables. It is now safe for you to open the doors in order to gain access to the fuses. You will now need to remove the "courtesy" fuse, and perform step 3.4 again.
 
Disconnect EITHER one of the DVOM cables. It is now safe for you to open the doors in order to gain access to the fuses. You will now need to remove the "courtesy" fuse, and perform step 3.4 again.
 
# Did the reading remain the same or very close?
 
# Did the reading remain the same or very close?
  Yes, it remained the same (it is still too high) - there is NOT a problem in this courtesy light circuit. Continue testing.  
+
  Yes - it remained the same (it is still too high) - there is NOT a problem
  No, the amperage reading is LESS than before - there WAS an excessive power draw in this circuit. THIS ''is'' the problem circuit.  
+
      in this courtesy light circuit. Continue testing.  
 +
  No - the amperage reading is LESS than before - there WAS an excessive power draw
 +
      in this circuit. THIS ''is'' the problem circuit.  
  
 
If readings are STILL in the UNACCEPTABLE range after checking this circuit you will now begin the FUSE PANEL isolation portion of this procedure.  
 
If readings are STILL in the UNACCEPTABLE range after checking this circuit you will now begin the FUSE PANEL isolation portion of this procedure.  